Dalian Aode Air Conditioning Technology Service Co., Ltd. +86 0411-85366638
Zou, director of Dalian Aode air conditioning Group Co., Ltd. Beijing Office +86 13810589128
Longyao Aolian Thermal Power Co., Ltd. +86 0319-6511666
Julu Aolian Thermal Power Co., Ltd. +86 0319-4230666
Address: No. 61, zone a, Yuanbao Industrial Park, Wafangdian, Dalian
Switchboard: +86 0411-85366638 85366639
Fax: +86 0411-85366637 85366635
Email: od8848@163.com
Website: www.dlaode cn
Postal Code: 116323
Installation points and precautions for Dalian air source heat pump unit
*
:
*
:
admin *
:
2024/10/31 14:16:02 *
:
4
As an efficient and environmentally friendly heating and cooling equipment, the correct installation of air source heat pump units is crucial for maximizing equipment performance, ensuring stable operation, and extending service life. The following are the installation points and precautions:
1、 Installation points
(1) Site selection
Choose a well ventilated location to ensure smooth air circulation around the unit, so as to fully absorb and release heat. Avoid installing the unit in narrow, enclosed spaces or near obstacles to avoid affecting air circulation and heat dissipation.
Considering the impact of the operating noise of the unit on the surrounding environment, it is recommended to install it in a location away from areas with frequent human activities such as bedrooms and living rooms. If necessary, sound insulation measures can be taken to reduce noise.
The installation site should have good drainage conditions to prevent rainwater or condensation from accumulating around the unit. You can set a drainage slope or install drainage pipes at the bottom of the unit to ensure smooth drainage.
(2) Basic installation
To create a stable foundation for the unit, the size and strength of the foundation should be designed according to the weight and size of the unit. Generally, concrete foundation or steel structure foundation can be used to ensure that the foundation can withstand the operating weight and vibration of the unit.
Install shock pads or dampers on the foundation to reduce the transmission of vibration and noise generated during unit operation to the building structure. The selection of shock pads or shock absorbers should be matched according to the weight and vibration frequency of the unit.
(3) Pipeline connection
When connecting water pipelines, it is necessary to ensure that the material of the pipeline meets the requirements, generally using PPR pipes or galvanized steel pipes. The connection of pipelines should be firm and sealed to avoid water leakage. During the installation process, attention should be paid to the slope and direction of the pipeline to ensure smooth water flow and avoid air or water blockages.
For the connection of refrigerant pipelines, it must be operated by professional technicians and welded or connected strictly according to the manufacturer's requirements. Ensure good sealing of refrigerant pipelines to avoid refrigerant leakage. After the connection is completed, a leak test of the system should be conducted to ensure that there are no leaks in the system.
(4) Electrical connection
Electrical connections must comply with national electrical safety standards and regulations, and be operated by professional electricians. Before connecting the power supply, check whether the rated voltage and frequency of the unit match the power supply to avoid damaging the unit due to voltage mismatch.
Install leakage protectors and grounding devices to ensure the electrical safety of the unit. The grounding resistance should meet the requirements, and the reliability of the grounding device should be checked regularly to prevent electric shock accidents.
2、 Precautions
(1) Safety precautions
During the installation process, construction personnel must wear personal protective equipment such as safety helmets and safety belts to ensure personal safety. Effective safety measures should be taken when working at heights to prevent falling accidents from occurring.
It is strictly prohibited to carry out installation and commissioning work under live conditions. The power supply must be cut off first, and electrical testing must be carried out to ensure that there is no power before starting work. At the same time, warning signs should be set up to prevent others from making mistakes.
(2) Environmental requirements
The ambient temperature at the installation site should be within the operating range of the unit, generally between -5 ℃ and 45 ℃. When installing in a low-temperature environment, it is important to take cold protection measures to prevent damage to the unit's pipelines and equipment due to low temperatures.
Keep the installation site clean and hygienic, and avoid dust, debris, etc. from entering the interior of the unit, which may affect the normal operation of the equipment. After installation, the unit should be cleaned and protected to prevent damage from external factors.
(3) Debugging and acceptance
After installation, system debugging work must be carried out to check whether the operating status, water temperature, pressure and other parameters of the unit are normal. During the debugging process, attention should be paid to observing the operation of the unit. If there are any abnormal phenomena, the machine should be stopped and checked in a timely manner. After troubleshooting, debugging can be carried out.
After installation, strict acceptance work must be carried out. The acceptance content includes the installation quality of the unit, the sealing of pipeline connections, the safety of electrical connections, and the operational performance of the system. Only when all acceptance indicators meet the requirements can it be delivered for use.
In short, the installation of air source heat pump units is a highly specialized task that requires strict adherence to installation points and precautions. Only through correct installation and debugging can the normal operation of the unit be ensured, providing users with comfortable and energy-saving heating and cooling services. During the installation process, if there are any questions or issues, the manufacturer or professional technicians should be consulted in a timely manner to ensure the smooth progress of the installation work.